Midas-M Gas Detector by Honeywell
The Midas-M is a Fixed Extractive Single Point with 4-in-1 Multi Gas Detector that draws a sample locally or from a remote point to a sensor cartridge that is located inside the detector’s chassis.
Fixed extractive, 4-in-1 multi gas detector. The Midas-M with 4-in-1 Multi Gas Detector to detect more than 30 gases – precisely, easily, quickly, that draws a sample locally or from a remote point to a sensor cartridge that is located inside the detector’s chassis. A side range of toxic, flammable and oxygen gas sensor cartridges are available that enable detection of gases used or generated in the Semiconductor and other manufacturing industries.
PLUG-AND-PLAY GAS DETECTION
With flexible features and options, the Midas-M Gas Detector works right out of the box and configures easily to meet your needs. Each plug-and-play sensor cartridge is pre-calibrated, so it’s ready when you are. That means longer sensor life, quick and easy replacement, and no operator error due to incorrect or depleted sensors. The Midas-M has flexible power and communications capabilities build in as standard. These include 3 on board relays, 0-21 mA analog output, Modbus/TCP outputs for signal and service connectivity as well as Power over Ethernet (POE) connection that enables a single Ethernet connection to be made for all power, control and communication requirements.

Front Display of the Midas-M Gas Detector

Lower cost of ownership- Fixed Extractive Single Point with 4-in-1 Multi Gas Detector
Easy to use interface – The Midas-M Gas Detector is equipped with large LCD display with individual multi colour back light and intuitive icons that provide instant alerts to gas readings or alarm levels.
Easy installation and maintenance – The Midas-M Gas Detector comprises of 4 parts: The main module, the mounting bracket assembly, the sensor cartridge and the pump module
Numerous applications – With feature rich capabilities that are easy to use, the Midas-M Gas Detector is suitable for various industry applications, including semiconductor processing, light industrial manufacturing, university laboratories, aerospace, wastewater and the others.
Detectable Gases - Honeywell Midas-M
Gas | Range |
---|---|
Hydrogen Chloride (HCl) | 0-8 ppm |
Boron Trichloride (BCl3) | 0-8 ppm |
Dichlorosilane (SiH2Cl2) | 0-8 ppm |
Hydrogen Bromide (HBr) | 0-8 ppm |
Silane (SiH4) | 0-20 ppm |
Disilane (Si2H6) | 0-20 ppm |
Hydrogen (H2) | 0-1000 ppm |
Chlorine (Cl2) | 0-2 ppm |
Ammonia (NH3) | 0-100 ppm |
Carbon Monoxide (CO) | 0-100 ppm |
Phosphine (PH3) | 0-1200 ppb |
Ozone (O3) | 0-0.4 ppm |
Oxygen (O2) | 0-25% v/v |
Sulfur Dioxide (SO2) | 0-8 ppm |
Hydrogen Fluoride (HF) | 0-12 ppm |
Boron Trifluoride (BF3) | 0-8 ppm |
Tungsten Hexafluoride (WF6) | 0-12 ppm |
Technical Specification of the Honeywell Midas-M Detector
Size: 136 mm (H) x 83 mm (W) x 152 mm (D)
Weight – Transmitter: 1.3 kg, Cartridge: 0.17 kg ~ 0.22 kg dependent on sensor type
Optional Relay Dimension: Size: 137 mm (H) x 84 mm (W) x 41 mm (D)
Weight: 0.31 kg
Operating Voltage: 24 VDC Nominal, -15 to 10% (20.4 VDC to 26.4 VDC)
Operating Voltage with Power Over Ethernet (PoE): 48 VDC PoE (IEEE 802.3af compliant)
Transmitter unit (normal condition): Typ. 5 W
Transmitter unit (full load condition): ≤ 11.45 W
Transmitter with Optional Relay: ≤ 12.9 W
Visual Outputs: Alarm, Power, Fault LEDs, and LCD with all the gas readings and events.
LEDs: Power (Green), Alarm 1 (Red), Alarm 2 (Red), Fault (Yellow)
Relays in Transmitter: (3) Relays for Alarm 1, Alarm 2 and Fault rated 1.0 A @ 30 Vdc or 0.5 A @ 125 Vac
Max 10 uA @ 10 mV minimum, configurable as normally open or closed, latched or unlatched
Relays in Optional Relay: 8 relays for Alarm 1 and Alarm 2 of each channel and a relay for common fault rated 1.0 A @ 30 Vdc or 0.5 A @ 125 Vac
Max 10 uA @ 10 mV minimum, configurable as normally open or closed, latched or unlatched
Analog Outputs
3 wire sink, 3 wire source, or 4 wire fully isolated; 0 mA to 21 mA for each channel
Digital Communications
Modbus/TCP Ethernet/Power over Ethernet (PoE)
Flow Rate
600 mL/min
Transport Time
2 seconds to 25 seconds maximum
Sample Line Tubing
3.18 mm ID x 6.35 mm OD
Tubing Length
Up to 30 m with FEP tubing
Exhaust Line Tubing
4.76 mm ID x 6.35 mm OD
Exhaust Length
Up to 30 m
Ambient Port
Inline air filter required
Operating Temperature
0°C to 40°C
4-20 mA Wiring Requirement
2 wire, 14 AWG maximum
Digital Wiring Requirement
CAT5 Cable or equivalent: RJ45 connector
Instrument Display
4-digit alphanumeric display with separate units, concentration bar graph for each channel and other icon-driven indicators. 4 button interface keypad
Remote Display
Internet browser access via Ethernet
Mounting
Wall-mounted using pre-drilled holes on chassis. Options for DIN rail
Material
Cover: Plastic (Polycarbonate)
Chassis/Mounting bracket: Zinc plated steel
Red frame: Liquid coated aluminum
Warranty
Transmitter Unit: 1 year
Sensor Cartridge: 2 years
Download Brochure for the Midas-M Detector in PDF
- Over *33 gases available with 2 year warranty : 17 gases available at launch
- 4-in-1 multi smart sensor cartridge with on board * ‘e-calibration’ certificate
- Modular design for easy to use and service (front, pump, sensor cartridge, main and base)
- 3 built in relays (Form C) for Alarm 1, 2 and Fault
- Power over Ethernet (POE) communication
- Keypad interface and remote web browser interface
- Factory-calibrated sensors to reduce need for frequent gas testing
- Isolated 0-20 mA analog output with fault and event reporting
- Modbus/TCP Ethernet for easy connectivity to all control and alarm systems ports for control connectivity and service interaction
- Robust extractive pump system (2 year lifetime) sampling up to 100 feet
Gas | Range |
---|---|
Hydrogen Chloride (HCl) | 0-8 ppm |
Boron Trichloride (BCl3) | 0-8 ppm |
Dichlorosilane (SiH2Cl2) | 0-8 ppm |
Hydrogen Bromide (HBr) | 0-8 ppm |
Silane (SiH4) | 0-20 ppm |
Disilane (Si2H6) | 0-20 ppm |
Hydrogen (H2) | 0-1000 ppm |
Chlorine (Cl2) | 0-2 ppm |
Ammonia (NH3) | 0-100 ppm |
Carbon Monoxide (CO) | 0-100 ppm |
Phosphine (PH3) | 0-1200 ppb |
Ozone (O3) | 0-0.4 ppm |
Oxygen (O2) | 0-25% v/v |
Sulfur Dioxide (SO2) | 0-8 ppm |
Hydrogen Fluoride (HF) | 0-12 ppm |
Boron Trifluoride (BF3) | 0-8 ppm |
Tungsten Hexafluoride (WF6) | 0-12 ppm |